Passive Tracers

A tracer is a depth-averaged concentration carried along by the water: a salinity, a dye release, a pollutant, a temperature proxy. It is passive — it is transported by the flow but does not affect it, so adding one never changes the hydrodynamics.

Tracers are the foundation suspended sediment is built on: a sediment grain size is a tracer with settling parameters attached, so everything on this page applies to sediment too. See Sediment transport.

The shortest useful program

import numpy as np

import anuga

domain = anuga.rectangular_cross_domain(20, 20, len1=100.0, len2=100.0)
domain.set_quantity('elevation', 0.0)
domain.set_quantity('stage', 1.0)
domain.set_quantity('xmomentum', 2.0)          # 2 m/s of flow to carry it

Br = anuga.Reflective_boundary(domain)
Bt = anuga.Transmissive_boundary(domain)
domain.set_boundary({'left': anuga.Dirichlet_boundary([1.0, 2.0, 0.0]),
                     'top': Br, 'bottom': Br, 'right': Bt})

# A tracer, released as a patch in the upstream half
domain.add_tracer('dye')
x = domain.centroid_coordinates[:, 0]
domain.set_tracer('dye', np.where(x < 50.0, 1.0, 0.0))

# The water flowing in at 'left' is clean. Say so: an unset inflow
# boundary would also bring c = 0, but silently -- see below.
domain.set_tracer_boundary('dye', 'left', 0.0)

domain.set_name('dye_release')
for t in domain.evolve(yieldstep=1.0, finaltime=60.0):
    print(domain.timestepping_statistics())

change, flux, discrepancy = domain.check_tracer_conservation('dye')
print('mass change %g, boundary flux %g, discrepancy %g'
      % (change, flux, discrepancy))

The plume advects downstream and leaves through the open right-hand boundary, so the mass falls and the boundary flux accounts for it exactly:

mass change -4999.9, boundary flux -4999.9, discrepancy 8.19e-12

The run writes dye_release.sww containing a dye_c variable, one value per cell per timestep.

What is actually conserved

The quantity the solver integrates is not the concentration but

\[m = h\,c\]

the mass per unit area, with \(h\) the water depth. The concentration \(c\) is derived from \(m\) each substep, exactly as height is derived from stage.

This matters in two places.

  • A dry cell carries no concentration. When \(h\) falls below minimum_allowed_height the derived \(c\) is zero, not the last wet value.

  • set_tracer() reads the current depth to form \(m = h c\), so set stage and elevation before the tracer, not after. Setting them afterwards leaves \(m\) inconsistent with the depth it was formed from.

Tracers are deliberately not Quantity objects. They live in one contiguous (n_tracers, N) block so the flux kernel can stride them and the GPU can map them in a single transfer. The practical consequence is that they do not appear in domain.quantities and cannot be named in quantities_to_be_stored; the accessors below are the interface.

Registering and setting

domain.add_tracer('salinity', initial_value=0.035)
domain.add_tracer('dye')                       # defaults to zero

domain.set_tracer('dye', 0.5)                  # uniform
domain.set_tracer('dye', array_of_len_N)       # one value per cell

domain.get_tracer('dye')                       # the concentration, per cell
domain.get_tracer_names()                      # in registration order

Order matters. A tracer’s slot is fixed at registration, and a sediment grain size occupies the tracer slot of the same index, so do not interleave add_tracer() and add_sediment_fraction() if you rely on that correspondence.

A tracer may not be named after a quantity. Both are written to the sww as <name>_c, so a tracer called stage would overwrite the stage in the output; add_tracer() refuses those names, and names beginning max_, which are reserved for running maxima.

Registering a tracer reallocates every tracer array, so a reference held to one beforehand goes stale. Add all the tracers first, then seed their values.

Reconstruction order

beta controls the edge reconstruction, analogous to beta_w for stage: 0 selects first order, > 0 a limited second order.

One value is shared by every tracer — the C domain carries a single beta_tracer scalar — so passing a second, different value is an error rather than a silent last-writer-wins:

domain.add_tracer('a', beta=1.0)
domain.add_tracer('b', beta=0.0)     # ValueError: beta is shared

Boundary concentrations

What a tracer brings in across a boundary is set per boundary tag:

domain.set_tracer_boundary('salinity', 'ocean', 0.035)
domain.set_tracer_boundary('salinity', 'river', 0.0)

# time varying: re-evaluated each timestep
domain.set_tracer_boundary('salinity', 'tide',
                           lambda t: 0.035 + 0.001 * math.sin(t / 4000.0))

# or one value per edge of that tag, ordered as domain.tag_boundary_cells[tag]
domain.set_tracer_boundary('salinity', 'river', per_edge_array)

The value is only used where water flows IN. The flux kernel picks the upwind concentration edge by edge from the sign of the water flux:

Flow at the edge

Concentration used

inflow (\(n \cdot U\) into the domain)

the boundary value set here

outflow (\(n \cdot U\) out of the domain)

the interior edge value

So there is nothing to set for an outflow, and nothing that can be set — prescribing a concentration on an outflow would over-determine the advection, and the kernel ignores it. A boundary that only ever lets water out needs no call at all, and one that alternates gets Dirichlet-on-inflow / transmissive-on-outflow automatically: the characteristic condition, with no switch to throw.

Warning

An unset boundary brings in \(c = 0\). The array is zero-filled at add_tracer(), so with no call an inflow carries clean water.

That is a modelling assumption, not a neutral default. For salinity or suspended sediment it is usually wrong, and it is invisible in the output — the run completes and the numbers look reasonable. Set it explicitly wherever water enters.

On a distributed sub-domain a tag this rank owns no part of is ignored, so the same call works on every rank. In serial an unknown tag is an error, where it can only be a typo.

Tracers at inlets, structures and rate operators

An Inlet_operator adds or removes water inside the domain, and the water it moves carries tracer:

# river inflow at a known sediment concentration (constant or f(t))
anuga.Inlet_operator(domain, river_line, Q=river_discharge,
                     tracer_concentrations={'mud': 4.8e-5,
                                            'sand': lambda t: sand_rating(t)})

# an outlet needs nothing: the water it pumps out takes its tracer with it
anuga.Inlet_operator(domain, outlet_line, Q=-500.0)
  • Inflow. The added water carries the concentration given for each tracer, a constant or a function of time (averaged over each step, as Q is). Tracers not named come in at \(c = 0\), the same modelling assumption as an unset boundary.

  • Extraction. The operator treats its region as one level pool, so the water leaves at the pool’s mean concentration and the cells left behind keep that concentration. Draining the region dry removes all of its tracer. In parallel the pool spans every rank holding part of the region.

Both are exact: the domain’s tracer changes by precisely what the water carried across the inlet, in either compute mode and in parallel. Each operator keeps the running totals in op.tracers.total_in and op.tracers.total_out, per tracer name. (Before 4.1 an outlet removed only water, so its tracer stayed behind and concentrated without bound as the cells drained.)

The inlet exchange is not a boundary flux, so a domain with inlets does not satisfy the identity in the next section; add the inlets’ net transfers to the boundary flux integral to close the budget.

Structures – culverts (Boyd_box_operator, Boyd_pipe_operator), weirs, bridges and internal boundaries – carry tracer through with the water they move, with nothing to set. Each cell of the inflow region that loses water keeps its concentration, and the tracer it gives up arrives in the outflow region with the water, spread over its cells in proportion to the water each gains. Tracer is conserved exactly, a structure that moves no water leaves the tracer untouched, and in parallel it is carried across sub-domains when the two ends are on different ranks. The running total is in op._structure_tracers.total_moved on the host paths. (Before 4.1 a culvert moved water only: the tracer stayed upstream and clean water arrived downstream.)

Structures move water inside the domain, so unlike inlets they do not change the domain’s tracer mass and the identity below still holds.

Rate operators add water over a region (rain, a distributed inflow) or take it away (a negative rate). What the tracers do is yours to choose:

# rain carrying a pollutant; clean rain is the default
anuga.Rate_operator.rainfall(domain, rate=20.0,
                             tracer_concentrations={'nitrate': 2.0e-6})

# a drain or pump: the tracer leaves with the water
anuga.Rate_operator(domain, rate=-1.0e-4, polygon=drain,
                    tracer_extraction='carry')

# evaporation: water leaves, salt stays (the default, 'retain')
anuga.Rate_operator(domain, rate=-2.0e-8, tracer_extraction='retain')

# one choice per tracer: dissolved nitrate infiltrates, sediment is filtered
anuga.Rate_operator(domain, rate=-5.0e-6,
                    tracer_extraction={'nitrate': 'carry', 'mud': 'retain'})

With 'carry' a cell keeps its concentration as it loses water, so draining it dry removes all of its tracer. With 'retain' the tracer stays however much water leaves; a cell drained dry keeps its tracer, which reappears when the cell rewets. Both are exact per cell and work in both compute modes. A rate operator with no concentration given and every tracer retaining does exactly what it did before 4.1, at no extra cost.

Checking conservation

The tracer counterpart of the water balance. For a domain with no source terms,

\[\text{mass}(t) - \text{mass}(0) = \text{boundary flux integral}(t)\]

to within the timestepping error.

domain.get_tracer_mass('dye')                   # integral of m = h*c
domain.get_tracer_boundary_flux_integral('dye') # net across the boundary
change, flux, discrepancy = domain.check_tracer_conservation('dye')

discrepancy is the conservation error. These return absolute quantities rather than a relative error: for a tracer that is zero almost everywhere a relative measure is meaningless, and you know the scale that matters.

Sign follows the water balance: positive is into the domain. Nothing needs setting up — add_tracer() registers the operator that accumulates the boundary flux, and the baseline is taken from the initial condition.

All three are collective in parallel, like get_water_volume(): every rank must call them, or the ones that do will block.

Running maxima

Collect_max_quantities_operator tracks the running maximum of every registered tracer alongside stage, depth and speed, stored in the sww as max_<name>_c:

from anuga.operators.collect_max_quantities_operator import (
    Collect_max_quantities_operator)

domain.add_tracer('dye')
Collect_max_quantities_operator(domain, store_to_sww=True)

Register the tracers before creating the operator: the names are fixed at construction, and an sww variable cannot appear after the file is created.

Note

The maxima do not sample the initial condition. Collection happens on the fractional-step call, which first runs after the first update, so a cell whose maximum is its starting value reports the first post-step value instead. This is long-standing behaviour for stage, depth and speed; the tracers follow it so that every max_* variable in an sww means the same thing.

Output and plotting

Each tracer is written as one dynamic centroid variable <name>_c. They are centroid quantities, so nothing is interpolated to vertices that the solver never computed.

The file names its own tracers in a tracer_names attribute — salinity_c is otherwise indistinguishable from stage_c — and the readers use it:

from anuga.utilities import plot_utils as util

util.get_tracer_names('dye_release.sww')     # ['dye']

p = util.get_centroids('dye_release.sww')
p.tracers['dye']                             # (ntimes, ncells)

tracers is a dict rather than an attribute per tracer, so a tracer can never shadow stage or vel. get_output exposes the same dict.

Tracers also appear in the sww GUI’s quantity menu as tracer_<name>, and their maxima as max_tracer_<name>, once a file containing them is loaded.

Set domain.store_tracers = False to keep them out of the sww.

Parallel and reordered domains

Tracers are carried through distribute() and survive reorder(). Register them and set their values before distributing:

if myid == 0:
    domain = build_domain()
    domain.add_tracer('salinity', initial_value=0.035)
else:
    domain = None

domain = anuga.distribute(domain)

# boundary concentrations AFTER distribute: they are sized by each
# sub-domain's own boundary
domain.set_tracer_boundary('salinity', 'ocean', 0.035)

The per-timestep halo exchange is handled for you. Each rank counts only the boundary edges of cells it owns, so the conservation figures above are whole-domain values, not per-rank ones.

Compute modes

Tracers work in both the legacy and unified compute modes, and on the GPU. The two modes agree to round-off, which is the property the GPU tests use as their oracle.

In unified mode the tracer state lives on the device between yield steps. That is invisible for ordinary use, but if you reach into the arrays directly — domain.tracer_centroid_values and friends — the host copy will be stale. Use the accessors, or pin the domain with domain.set_compute_mode('legacy').